Setting the Operations from the Viewer Page — Trigger setting Menu

60

procedures are the same as those of the Image Memory
setting menu (page 53).

Alarm output

After checking this, you will be able to select Alarm
output
in the Trigger setting menu. You can control On
(short circuit ) or Off (open) by selecting Alarm output
and clicking the Trigger icon.

One Time Tour

After checking this, you will be able to select One time
tour
in the Trigger list box.
Select One time tour in the trigger box and click the
trigger icon, then One time tour starts.
Up to 8 positions can be programmed, and the camera
moves to the programmed positions sequentially. The
camera stops when it moves to the last preset position.

When you click One time tour, One time tour setting
menu is displayed.

Stay time
Set the stop time in each preset position (1 to 3600
seconds).

Speed
Select the moving speed from the list box.
The value is higher, the moving speed is faster.

Sequence
Select and set the preset number 1 to 8 for each of 8 list
boxes.
The camera moves to the preset position saved in the
selected preset number sequentially. The sequence of
camera movement starts from the preset position
specified in the list boxes from left to the right. The
camera stops when it moves to the right most.
If you select End in the list box, the program ends before
it and the camera stops.