Outdoor Unit CM2472

Insulation of Refrigerant Tubing

Because capillary tubing is used in the outdoor unit, both the

wide and narrow tubes of this air conditioner become cold. To

prevent heat loss and wet floors due to dripping of

condensation, both tubes must be well insulated with a

proper insulation material. The thickness of the insulation

should be a min.5/16"(8 mm).

After a tube has been insulated,

never try to bend it into a narrow

curve because it can cause the tube

to break or crack.

Wide tube

Thickness:

Min.5/16"(8 mm)

Insulation

Narrow tube

Thickness:

Min.5/16"(8 mm)

IMPORTANT

CAUTION

Service valve on

narrow tube

Electric

expansion

valve

Service valve on

wide tube

DN

CN

BN

AN

DW

CW

BW

AW

O.D.1/4"

O.D.1/4"

O.D.1/4"

O.D.1/4"

O.D.3/8"

O.D.3/8"

O.D.3/8"

O.D.1/2"

Cooling cycle

Strainer

Header

Header

M

M

M

M

Indoor unit

Outdoor unit

Wide tube

Narrow tube

Compressor

High pressure

switch

H.P.

Main

accumulator

Sub

accumulator

Heat exchanger