3

1. General

This booklet briefly outlines where and how to install the

air conditioning system. Please read over the entire set

of instructions for the indoor and outdoor units and make

sure all accessory parts listed are with the system before

beginning. If the electric wiring diagram does not appear

in this manual, please check for the diagram on the

indoor unit.

1-1. Tools Required for Installation (not supplied)

1. Standard screwdriver

2. Phillips head screwdriver

3. Knife or wire stripper

4. Tape measure

5. Carpenter’s level

6. Sabre saw or key hole saw

7. Hacksaw

8. Core bits

9. Hammer

10. Drill

11. Tube cutter

12. Tube flaring tool

13. Torque wrench

14. Adjustable wrench

15. Reamer (for deburring)

16. Vacuum pump (For R410A)

17. Manifold valve

1-2. Accessories Supplied with Unit

Table 1

1-3. Optional Copper Tubing Kit

Copper tubing for connecting the outdoor unit to the

indoor unit is available in kits which contain the narrow

and wide tubing, fittings and insulation. Consult your

nearest sales outlet or A/C workshop.

1-4. Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately from

a local source, you will need:

1.

Deoxidized annealed copper tube for refrigerant tub-

ing as detailed in Table 2.

Cut each tube to the appropriate lengths 1' to 1'4"

(30 cm to 40 cm) to dampen vibration between units.

Table 2

2.

Foamed polyethylene insulation for the specified

copper tubes as required to precise length of tubing.

Wall thickness of the insulation should be not less

than 5/16" (8 mm).

3.

Use insulated copper wire for field wiring. Wire size

varies with the total length of wiring.

Refer to 5. Wiring Instructions for details.

Labels for inter-unit
cable and tube

Reducer
(3/8" 1/2")

1

Packed in the outdoor unit.

1

4 each

Hex wrench

Cushion rubber

4

Parts

Figure

Q’ty

Parts

Figure

Q’ty

Parts

Figure

Q’ty

1972

2472

3172

2

1

A B C D

Reducer
(1/2" 3/8")

CAUTION

Check local electrical codes

and regulations before

obtaining wire. Also, check

any specified instructions or

limitations.

Model

Narrow Tube

Wide Tube

Outer Dia.

Thickness

Outer Dia.

Thickness

KMS0772

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

KMS0972

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

KMS1272

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

KMS1872

1/4" (6.35 mm)

0.0314" (0.8 mm)

1/2" (12.70 mm)

0.0314" (0.8 mm)

KMS2472

1/4" (6.35 mm)

0.0314" (0.8 mm)

5/8" (15.88 mm)

0.0393" (1.0 mm)