2-6.

Diagram of Outdoor Unit Installation

Never install only a single indoor unit.

Be sure to connect indoor and outdoor units only in
combinations that are listed in the catalog or in the
combination table that was provided with the outdoor unit.
(Use caution. Connecting any other model may result in
operation failure and malfunction.)

The dimensions indicated by

in the figure below are

spaces that are required in order to maintain
performance. Install in a location where the dimensions
indicated by

are ensured, and where 2 or more faces

of the unit are unobstructed. In principle, the top direction
should be unobstructed.

Indoor unit C

Indoor unit B

Indoor unit A

Indoor unit D

Service space

Power breaker

Ground
wire
(not
provided)

Ensure 6"(15cm)
of space if a
drain hose is to
be used.

Base (not provided)
(concrete or similar material)

Fasten with anchor bolts
(not provided)
(3/8" or M10, 4 locations)

A

B

C

D

Access panel C

Ov

er 10"(25cm)

Ov

er 8

"(2

0cm)

Ov

er 4"(10cm)

Ov

er 1'

8"(50cm)

Fig. 7