Performance data, 1. temperature charts, Cooling characteristics – Sanyo CM1972 User Manual

Page 22

Advertising
background image

Cooling Characteristics

(RH : 46%, Indoor fan speed : High fan)

(230V, 60Hz)

(1) Low pressure performance chart

(2) Operating current performance chart

(3) Indoor discharge air performance chart

• This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on

the indoor unit type.

• Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value.

(In this case, be sure to stop all the indoor units where performance is not being checked.)

• The performance is for a tubing length of 24.6t (7.5m). If the tubing length is different, the performance chart will vary.

NOTE

Low pressure at wide tube service valve

psig (MPaG)

Outdoor air temperature °F (°C)

174

(1.2)

188

(1.3)

160

(1.1)

146

(1.0)77

(25)

86

(30)

95

(35)

104

(40)

Lo fan

Hi fan

HH fan

Operating current (A)

Outdoor air temperature °F (°C)

4

5

3

2

Lo fan

Hi fan

HH fan

Indoor discharge air temperature °F (°C)

Outdoor air temperature °F (°C)

46.4( 8)

68.0(20)

64.4(18)

60.8(16)

57.2(14)

53.6(12)

50.0(10)

Lo fan

Hi fan

HH fan

Outdoor Unit CM1972 Indoor Unit KMS0772

×

1

5-1-1. Temperature Charts (CM1972)

77

(25)

86

(30)

95

(35)

104

(40)

77

(25)

86

(30)

95

(35)

104

(40)

5. PERFORMANCE DATA

5-1. Temperature Charts

Indoor air tem

p. 86°F (30°C)

80°F (27°C)

75°F (24°C)

Indoor air temp. 86°F (30°C)

80°F (27°C)

75°F (24°C)

Indoor air temp. 86°F (30°C)

80°F (27°C)

75°F (24°C)

22