Siemens SCALANCE X-200 User Manual

Page 48

Advertising
background image

Product Characteristics

4.4 SCALANCE X206-1

0 – 85 m


0 -3,000 m

IE FC marine/trailing cable with IE FC RJ-45 plug

180

or

IE FC marine/trailing cable (0 - 75 m) + 10 m TP

cord
Glass FOC
62.5/125 µm or 50/125 µm glass fiber;
≤ 1 dB/km at 1300 nm;

600 MHz x km;
6 dB max. permitted FO cable attenuation with 3

dB link power margin

Aging time
Aging time

5 minutes

Permitted Environmental Conditions / EMC
Operating temperature

0° C through +60° C

Storage/transport temperature

-40° C through +80° C

Relative humidity in operation

‹ 95% (no condensation)

Operating altitude

2000 m at max 56 °C ambient temperature

3000 m at max. 50 °C ambient temperature

RF interference level

EN 50081-2 Class A

Noise immunity

EN 50082-2

Degree of protection

Tested to IP30

Approvals

UL 60950

c-UL-us

CSA C22.2 No. 60950

c-Ul-us for hazardous locations

UL 1604, UL 2279Pt.15

FM

FM 3611

C-TICK

AS/NZS 2064 (Class A).

CE

EN 50081-2, EN 50082-2

ATEX Zone 2

EN50021

MTBF
MTBF

42.56 years

Construction
Dimensions (W x H x D) in mm

60 x 125 x 124

Weight in g

780

Installation options

Standard rail
S7-300 standard rail
Wall Mounting

Order Numbers
SCALANCE X206-1

6GK5206-1BB00-2AA3

Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line

4-34

Commissioning Manual, 1,

Advertising
This manual is related to the following products: