Diagnostics over Industrial Ethernet

6.2 Web Based Management (WBM)

Displays the user name for write access to SNMP variables. Here, changes can only be

made, when write protection (SNMP read only) has been disabled.

6.2.4.16 The "Agent Trap Configuration" WBM Menu

Agent Trap Configuration - SNMP Traps for Alarm Events

If an alarm event occurs, the SCALANCE X-200 can send traps (alarm frames) to up to two

different (network management) stations at the same time. Traps are sent only for events

specified in the Agent Event Configuration menu.

Figure 6-21 "Agent Trap Configuration" Dialog

IP Address Text Boxes
Here, you enter the addresses of the stations to which the SCALANCE X‑200 will send traps.
Enable Trap Check Box
Click on the check box next to the IP addresses to enable the sending of traps to the

corresponding stations.

Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,

6-25