Scalance x204-2 displays – Siemens SCALANCE X-200 User Manual

Page 56

Advertising
background image

Product Characteristics

4.5 SCALANCE X204-2

Notice
The C-PLUG may only be inserted or removed when the power is off!

Removing the C-PLUG

It is only necessary to remove the C-PLUG if the basic device develops a fault.
The C-PLUG can be removed from the slot using flat pliers, tweezers, or a small screwdriver.

4.5.9

SCALANCE X204-2 Displays

Fault indicator (red LED)

Status

Meaning

lit red

The SCALANCE X204-2 detects an error. At the same time, the

signaling contact opens.
The following faults are detected:
1. Link down event on a monitored port
2. Failure of one of the two redundant power supplies.
3. Device startup, the LED is lit for approx. 20s.

flashes red

An internal fault was detected.

Notify the maintenance personnel and, if necessary, send the

device in for repair.

not lit

No fault detected by the SCALANCE X204-2.

Power indicator (green LED)

The status of the power supply is indicated by two green LEDs:

Status

Meaning

lit green

Power supply L1 or L2 is connected.

not lit

Power supply L1 and/or L2 not connected or <14 V.

Port status indicator (green/yellow LEDs)

The status of the ports is indicated by six LEDs:

Status

Meaning

Port 1 through 8 LED lit green

TP link exists, no data reception

Port 1 through 8 LED lit yellow

TP link exists, data received at TP port

Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line

4-42