Working with the primary setup tool, Configuring a module – Siemens SCALANCE X-200 User Manual

Page 72

Advertising
background image

Diagnostics over Industrial Ethernet

6.1 Configuration with the Primary Setup Tool

4. Click the Install button in the General tab .
5. In the Network Component Type dialog, select Protocol and click the Add button. .
6. In the Network Protocol dialog box, Have Disk button. .
7. In the Install from Disk dialog box, click the Browse button. .
8. In the file selection dialog, change to the installation folder of the Primary Setup Tool

(default C:\Program Files\Siemens\Primary Setup Tool\) and open the DLC Protocol

subfolder.

9. Select the NETDLC.INF file and click the Open button.
10. In the Install from Disk dialog box, click the OK button. The protocol is installed, the DLC

Protocol entry is added to the list box in the Properties dialog box of the communications

module (Windows 2000/XP) for Siemens Primary Setup Tool.

11. Close the Properties dialog box by clicking on the OK button

6.1.5

Working with the Primary Setup Tool

Language Selection

After starting the Primary Setup Tool for the first time, a dialog box opens in which you set

the language for the program. You can also set the language separately in the Settings >

Language menu.

Selecting the Network Adapter

If there is more than one network adapter in your computer, you can open the Settings >

Network Adapter menu and specify which adapter is used by the Primary Setup Tool for

network access. This menu displays a maximum of four network adapters, however only

those for which the DLC protocol is activated are shown.

Browsing the Network

Before you assign IP addresses with the PST, you must first locate the configurable devices

in the network. Start this search with the steps outlined below:
• Select the Network > Browse menu command.

• Press the F5 function key.

• Click on the magnifier icon in the toolbar below the menu bar.
While the Primary Setup Tool browses the network, the Browse Network dialog is displayed

with a progress bar. On completion of the search, the Primary Setup Tool displays a list with

all the devices it has found in the left-hand pane.

6.1.6

Configuring a Module

If you click an entry in the list, the Primary Setup Tool displays information on the selected

device in the right-hand pane.

Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line

6-4

Commissioning Manual, 1,

Advertising
This manual is related to the following products: