Agent E-Mail Configuration - Network Monitoring with E-Mails

The SCALANCE X-200 provides you with the option of automatically sending an E-mail (for

example to a network administrator) if an alarm event occurs. The E-mail contains the

identification of the sending device, a description of the cause of the alarm in plain language,

and a time stamp. This allows centralized network monitoring to be set up for networks with

few nodes based on an E-mail system. When an E-mail event message is received, the

WBM can be started by the browser using the identification of the sender to read out further

diagnostic information.
E-mails can only be sent when
• the E-mail function is activated on the SCALANCE X-200 and the E-mail address of the

recipient is configured.

• the E-mail function is enabled for the relevant event.

• there is an SMPT server in your network that can be reached by the SCALANCE X-200.

• the IP address of the SMPT server is entered on the SCALANCE X-200.

Figure 6-19 "Agent E-Mail Configuration" Dialog

E-Mail Address Text Box
Here, you enter the E-mail address to which the SCALANCE X-200 sends an E-mail if a fault

occurs.
SMTP Server IP Address Text Box

Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line