The "agent event configuration" wbm menu, 13 the "agent event configuration" wbm menu – Siemens SCALANCE X-200 User Manual

Page 89

Advertising
background image

Diagnostics over Industrial Ethernet

6.2 Web Based Management (WBM)

Figure 6-17 "Agent Configuration" Dialog

IP Address Text Box
The IP address of the SCALANCE X-200. If you make a change here, the WBM loses the

connection to the SCALANCE X-200. Enter the new address in the Internet browser to

reestablish the connection.
Subnet Mask Text Box
Here, you enter the subnet mask of the SCALANCE X-200.
Default Gateway Text Box
If the PC with the Internet browser is not in the same subnet as the SCALANCE X-200, you

must enter the IP address of the default gateway here.

6.2.4.13 The "Agent Event Configuration" WBM Menu

Agent Event Configuration

On this page, you specify how the SCALANCE X-200 reacts to system events. By selecting

the corresponding check box, you specify how the SCALANCE X-200 reacts to the various

events The following options are available:
• The SCALANCE X-200 sends an E-mail.

• The SCALANCE X-200 triggers an SNMP trap.

Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,

6-21

Advertising