DataNET Hub Signal Equalizer Board,

Continued

Selec-
tion

Ratio

DB

loss

SW1

SW2

SW3

1 2 3 1 2 3 1 2 3

1

1

0

on on off on on off on on off

2

1.5

3.5 off off on on on off on on off

3

2.2

6.8 on on off off off on on on off

4

3

9.4 off off on off off on on on off

5

3.5

11 on on off on on off off off on

6

4.1

12.3 off off on on on off off off on

7

4.8

13.6 on on off off off on off off on

8

5.2

14.3 off off on off off on off off on

Calculation One:

Assume connections to Port 1 and Port 2 only.
Port 1 cable = 1000 ft. in length
Port 2 cable = 4000 ft. in length (3000 ft. difference)

Result:

Based on Table 2-2 data,
Port 1 requires compensation for 3000 ft. Selection 4 (2500-3500 feet)
Port 2 requires no compensation. Selection 1 (0 dB loss)

Calculation Two:

Assume connections to Port 1, Port 2, and Port 6
Port 6 cable = 5000 feet
Port 1 cable = 1000 ft. (5000 ft. - 1000 ft. = 4000 ft. difference)
Port 2 cable = 4000 ft. (5000 ft. - 4000 ft. = 1000 ft. difference)

Result:

Based on Table 2-2 data,
Port 6 requires no compensation. Selection 1 (0 dB loss)
Port 1 requires compensation for 4000 ft. Selection 6 (3500 - 4500)
Port 2 requires compensation for 1000 ft. Selection 2 (500 - 1500 ft.)

Note that the lengths of Port 1 and Port 2 cable are the same as in Cal-
culation One, however, with the addition of a longer length for Port 6,
new settings are required for Port 1 and Port 2.

Table 2-2. Recommended
Equalizer Board Settings

Sample Calculations