Siemens DataNET Hub (DNH) User Manual

Page 49

Advertising
background image

2000585-001

Installation

•••• 41

Signal Equalizer Settings for Non Recommended Cable or Unknown
Cable Lengths,

Continued

Step Action

3. cont

.

The next strongest signal is on port 6. 4.8/1.25 = 3.84

20 log of 3.84 = 11.7 dB

or
ratio of 3.84

Since this signal is 11.7 dB stronger than the signal on port 4,
the attenuator board on port 6 needs to be set to selection 5
(11 dB loss). This should put this signal at about 0.7 dB
above the signal on port 4. (Selection 6 could also be used
for 12.3 dB loss if several of the other boards had been set
for signals slightly below the port 4 signal level.)

4.

Ensure that the responses on all ports are within 3 dB of each
other

Example:

Port #

Resulting signal level refer-
enced to port 4

1

+ 2.1 dB

2

- 0.6 dB

4

0 dB

6

+ 0.7 dB

8

+ 0.1 dB