Sanyo AHX0952 User Manual

Page 53

Advertising
background image

K

53

(2) Check with a tape measure or carpenter’s level. This is

important so that the unit is correctly installed. (Fig. 3-117)

(3) Make sure the panel is flush against the wall. Any space

between the wall and unit will cause noise and vibration.

b) If the Wall is Brick, Concrete or Similar
Drill 3/16" dia. holes in the wall. Insert Rawl plugs for
appropriate mounting screws. (Fig. 3-118)

3-32. Removing the Grille to Install the Indoor Unit

In principle, with this model wiring can be completed without
removing the grille.
However, if it is necessary to change the settings on the PCB,
follow the procedure below.

Removing the grille

(1) Lift up on both sides of the air-intake grille to open it.

(Fig. 3-119)

(2) Remove the filter. (Fig. 3-119)

(3) Adjust the flap so that it is horizontal. (Fig. 3-120)

(4) Open the installation screw covers below the grille

(3 locations). (Fig. 3-120)

(5) Remove the screws. (Fig. 3-120)

(6) Remove the grille. (Fig. 3-121)

Attaching the grille

(1) Close the flap.

(2) Keep the grille installation tabs aligned with the top portion of

the grille, and reinstall the lower portion of the grille.
Fit the installation tabs into the grooves and press the lower
portion of the grille back into its original position to install it.

(3) Press on the installation tabs to completely close the grille.

Check that the grille and frame are fitted tightly together.

3-33. Preparing the Tubing

(1) Arrangement of tubing by directions

a) Right or left tubing

The corner of the right or left frame should be cut with a
hack saw or similar. (Fig. 3-122)

b) Right-rear or left-rear tubing

In this case, the corners of the frame do not need to be
cut.

(2) Be sure to insulate the part of the drain hose that is

run indoors, and the refrigerant tubing.
If these are not insulated, condensation may result in
dripping and damage to walls and furniture.
The flare nuts on the 24-type (only) are large;
therefore, use the supplied insulation material.

Fig. 3-117

Fig. 3-118

Fig. 3-119

Fig. 3-120

Fig. 3-121

3/16"
dia. hole

Rawl plug

Filter

Flap

Open the grille

Intake grille

Installation screw cover

Remove the grille

Fig. 3-123

Frame

Right tubing
outlet

When left and right side tubing

Fig. 3-122

Installation tabs

Installation tabs

07-056 Mini_ECOi_II_NA 3/19/07 2:41 PM Page 53

Advertising