6-4. Taping the Tubes

(1) At this time, the refrigerant tubes (and electrical

wiring if local codes permit) should be taped

together with armoring tape in 1 bundle. To prevent

the condensation from overflowing the drain pan,

keep the drain hose separate from the refrigerant

tubing.

(2) Wrap the armoring tape from the bottom of the

outdoor unit to the top of the tubing where it enters

the wall. As you wrap the tubing, overlap half of

each previous tape turn.

(3) Clamp the tubing bundle to the wall, using 1 clamp

approx. each ft. (Fig. 6-10)

Do not wind the armoring tape too tightly since this will

decrease the heat insulation effect. Also ensure that

the condensation drain hose splits away from the

bundle and drips clear of the unit and the tubing.

6-5. Finishing the Installation

After finishing insulating and taping over the tubing, use

sealing putty to seal off the hole in the wall to prevent

rain and draft from entering. (Fig. 6-11)