Maintenance indicators, Appendix – Sharp XG-C60X User Manual

Page 87

Advertising
background image

Appendix

-83

Maintenance Indicators

The warning lights on the projector indicate problems inside the projector.

If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate

red, and the projector will enter the standby mode. After the projector has entered the standby
mode, follow the procedures given below.

Temperature warning

indicator

Lamp indicator

Power indicator

About the temperature warning indicator

If the temperature inside the pro-
jector increases, due to blockage
of the air vents, or the setting lo-
cation, “

” will blink in the

lower left corner of the picture. If
the temperature keeps on rising,
the lamp will turn off and the tem-
perature warning indicator will
blink, the cooling fan will run for
further 90 seconds, then the pro-
jector will enter the standby mode.
After “

” appears, be sure to

perform the following measures.

About the lamp indicator

■ The lamp life becomes 0%, when used

for approximately 3,000 hours with “ON”
in “Power Save” or when used for approxi-
mately 2,000 hours with “OFF” in “Power
Save” (see page

69

).

■ When the remaining lamp life becomes

5% or less, “

” will be displayed on the

screen in yellow. When the percentage
becomes 0%, “

” will change to “

(red), the lamp will automatically turn off
and then the projector will automatically
enter the standby mode. At this time, the
lamp indicator will illuminate in red.

■ If you try to turn on the projector a fourth

time without replacing the lamp, the pro-
jector will not turn on.

Maintenance indicator

Condition

Problem

Possible Solution

Temperature

warning

indicator

Normal

Abnormal

Off

Red on/
Standby

The internal
temperature is
abnormally high.

Abnormal

Blocked air intake

Relocate the projector to an area
with proper ventilation.

Cooling fan break-
down

Internal circuit failure

Clogged air intake

Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see page

96

)

for repair.

Lamp

indicator

Red on/
Standby

The lamp does
not illuminate.

Burnt-out lamp

Lamp circuit failure

Carefully replace the lamp. (See
page

86

)

Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see page

96

)

for repair.

Please exercise care when
replacing the lamp.

Green on

Green

blinks

when the

lamp is

warming up

or shutting

down.

Red blinks/
Red on

Time to change
the lamp

Remaining lamp life
becomes 5% or
under.

Power

indicator

The power
indicator blinks
in red when the
projector is on.

The filter cover, lamp
unit cover or lens
cover is open.

Securely install the covers.

If the power indicator blinks even
when the filter cover is securely
installed, contact your nearest
Sharp Authorized Projector Dealer
or Service Center for advice.

Green on/
Red on

Red blinks

XG-C60X_E_PDF_p79_93.p65

03.8.28, 2:28 PM

83

Advertising