Konica Minolta Polygon Editing Tool User Manual

Page 41

Advertising
background image

39

Chapter

2

File
Menu

9i

File – Import – Digitizer – One Scan (When VIVID 9i is Selected)

Parameters for [File-Import-Digitizer-One Scan] Dialog Box

AF

Executes auto-focus.

Note

This parameter is effective only when VIVID 9i is connected.

Distance

Checking this checkbox enables distance setting.

Note

This parameter is effective only when VIVID 9i is connected.

Intensity

Checking this checkbox enables LD and Gain setting.
• LD:

Sets the laser power.

• Gain:

Sets the gain. The gain cannot be set if the “Standard” scan mode has been selected.

Note

This parameter is effective only when VIVID 9i is connected.

Scan

Performs a scan.

Note

This parameter is effective only when VIVID 9i is connected.

Import CDK

Imports the stored data (CDK) that was scanned by the VIVID 9i.
If data containing coordinate conversion parameters is imported, it will be stored automatically
even though it contains multiple scan data. In the case of data that has been stored, only the first
scan data will be imported.

Color Read

Takes a color shot. Clicking this button at the end of scan will take a color shot again and display
the updated color image.

Note

This button is effective if the [Use Color] checkbox is checked.

Edit

Clicking this button enables you to delete the area that is not necessary for threedimensionalization
by specifying it in the Work window using the mouse.

Auto Store

If this checkbox is checked, data save will be performed automatically when corresponding points
are designated in the Work and Store window areas.

Store

Registers the data present in the Work window area as store data, puts it into three-dimensional
form and displays it in the element view window.

Mono/Color/Pitch

Switches display mode for the data currently displayed in the Work window area.
• Mono: The current image is displayed in monochrome. This parameter is effective only when

VIVID 9i is connected.

• Color: The color data acquired from the scan is displayed.
• Pitch: The color display is done in accordance with the distance data from Near to Far.

Angle

Rotates the rotary stage to the desired angle using the slide bar.
This item is displayed when the rotary stage has been initialized successfully.

Prev/Next

Switches from one stored data to another.
[Prev] button: Displays the previous data.
[Next] button: Displays the next data.

Delete

Deletes the stored data currently displayed in the Work or Store window area. The corresponding
elements in the element view window are also deleted at the same time.

View

Displays/hides the data currently displayed in the Store window area into the element view win-
dow.

OK

Keeps the element data created during command execution and exits the File-Import-Digitizer-
One Scan
command.

Note

If the [Save Raw Data] checkbox is checked, the data save dialog box is displayed.

Cancel

Exits the File-Import-Digitizer-One Scan command.
The element data created during command execution will be deleted.

Option

Displays the [File-Import-Digitizer-One Scan-Option] dialogbox.

Calibration

Executes the Calibration command and calibrates the VIVID 9i.

Note

Have the Field Calibration System ready.

Ref.

For details on user calibration, refer to VIVID 9i Instruction Manual.

Advertising