95

Chapter

2

File
Menu

900

910

File – Import – Digitizer – Step Scan (When VIVID 900/910 is Selected)

Parameters for [File-Import-Digitizer-Step Scan] Dialog Box

Hardware Tab

Auto SCSI ID

Check this checkbox if you want the program to automatically check SCSI connections for
VIVID units. If this checkbox is not checked, the program will recognize VIVID units at specified
SCSI IDs only.

Mounted

• Vertical :

Check this checkbox if using the VIVID unit in vertical orientation.

• Horizontal : Check this checkbox if using the VIVID unit in horizontal orientation.

Apply

To change the rotation stage being controlled: Select the appropriate serial port and rotation
stage, and then click [Apply].

Note

If connecting to a SKIDS-60YAW unit, select “CSG-602R(Ver.1.0)” from the pull-down menu. If con-
necting to a SKIDS-60YAW (Ver. 2.0) unit, select “CSG-602(Ver.2.0)”.

Rotation Step

Sets the rotational step, in degrees. You can set this to 90, to 60, or to “Other”. If you select
“Other”, you can proceed to enter your own custom setting.

Current angle

Selects the scanning step (the scan angle). When the dialog box opens, the setting is “0”.
To change the setting, left-click on the angle to open the pull-down menu, and then enter the
scanning step (angle) that you wish to use. If you enter an angle that was already used for a scan
and then proceed to click the [Scan] button, the new scan data will overwrite the previous data
for that angle.

Check Scanning area

Turns the rotating stage through the angle set by the Rotation Step setting, while displaying
a monochrome image in the preview window.

Bench Top Frame Set

Checking this item enables the [Auto Scan] function.

Auto Scan

The program automatically scans over the angle set by the [Rotation Step] setting, and automati-
cally reads in the resulting camera data.

Chart File Data

Displays the information ([Lens Type], [Mode], [Distance], [Setting]) of the saved calibration data.

Parameters for [File-Import-Digitizer-Step Scan-Convert] Dialog Box

Reduction Rate

Selects the reduction rate to be applied when importing the data. You can select any of the follow-
ing: “1/1”, “1/4”, “1/9”, “1/16”, or “No polygon”.

Fill Holes

Selects whether the programs fill in holes when importing the data. If the setting is “On”, the pro-
gram will automatically generate points to fill in holes left by missing data.

Remove

Selects which the data the program excludes when carrying out the import. Select from an of the
following: “None”, “Boundary (B.)”, “5deg. & B.”, “10deg. & B.”, “15deg. & B.”, or “20deg. & B.”

None:

Removal is not carried out when importing the data.

Boundary(B.):

The program removes boundary points.

5deg. & B.,10deg. & B., 15deg. & B., 20deg. & B.:

The program removes boundary points, and also removes polygons within the
specified angular range (5°, 10 °, 15°, or 20°) to the view vector

Filter

None: The program does not perform filtering when importing the data.

Noise Filter (N.F.): When importing the data, the points that appear to be noise will be corrected

according to other data.

High Quality (H.Q.): The program filters out unreliable data. (Effective only when importing data

that was scanned using the VIVID 910.)

H.Q & N.F.:

Applies both noise filter and high quality filter. (Effective only when importing
data that was scanned using the VIVID 910.)

Save CDM

Save the images as camera data.

Advertising