Konica Minolta Polygon Editing Tool User Manual

Page 68

Advertising
background image

66

Chapter

2

File
Menu

910

File – Import – Digitizer – Step Scan (When VIVID 910 is Selected)

Parameters for [File-Import-Digitizer-Step scan-Option] Dialog Box

Scan Parameter

Mode

Select the scanning mode : FINE or FAST

Scan Parameter

• Load:

Loads the setting parameters from VIVID 910

and uses them as parameters for this

command.

• Save:

Saves the parameters set by this command to VIVID 910 as the setting parameters.

Dynamic Range Expan-
sion

Mode

If this button is checked, the program takes multiple shots so as to expand the dynamic range and
reduce data loss. This button is displayed only for the VIVID 910.

Brightness

Checking this checkbox enables you to set the brightness of the image.

Use Color

Checking this checkbox takes a color shot when a scan is made.

Log

Performs log correction for the color data if this checkbox is checked. This correction is used to
make neutral colors brighter.

Dark

Performs dark correction for the color data if this checkbox is checked. This correction is used
when lines are noticeable in the color image.

Convert Parameter

Save Raw Data

Checking this checkbox displays the data save dialog at the end of the File-Import-Digitizer-
Step Scan
command, allowing you to save the data.

Reduction Rate

Used to select the number of data points to be read from “1/1”, “1/4”, “1/9”, “1/16” and “No Polygon”.

Filter

• None :

Performs no correction for points when reading data. This can be set for
User mode only.

• Noise Filter (N.F.) : Reduces noise in points when reading data.
• High Quarity (H.Q.) : Deletes low-reliable data when reading data.
• H.Q. & N.F. :

Reduces noise in points and deletes low-reliable data when reading data.

Fill Holes

If “ON” is selected, points are generated in the holes that were produced as a loss of data so that
the holes are filled.

Remove

Select the data to be deleted when reading data.

• None :

Outputs the data without performing specific processing.

• Boundary (B.) :

Outputs the data after deleting boundary points.

• 5deg & B./10dwg & B./15deg. & B./20deg & B.:

Outputs the data after deleting the points present inside and at the bound

ary of the polygons that are angled within approximately 5, 10, 15 and 20

degrees to the vector of the line of view.

Hardware Parameter

• Vertical :

Check this checkbox if using the VIVID unit in vertical orientation.

• Horizontal :

Check this checkbox if using the VIVID unit in horizontal orientation.

Note

After changing the setting orientation, the Calibration Chart data of the rotating stage must be acquired
again before measuring.

Stage Parameter

Select the Port and Model to be used and click the [Apply] button. The rotary stage will be
initialized. If initialization is successful, the rotary stage can be controlled in the [File-Import-
Digitizer-Step Scan] dialog box.

Rotation Step

Select rotating angle for each step of rotary stage.

Default

Restores the default parameter settings.

OK

Closes the [File-Import-Digitizer-Step Scan-Option] dialog box.
The settings will be set.

Cancel

Closes the [File-Import-Digitizer-Step Scan-Option] dialog box.
The settings will be cancelled.