Nwhen using the bench top frame set – Konica Minolta Polygon Editing Tool User Manual

Page 86

Advertising
background image

84

Chapter

2

File
Menu

900

910

File – Import – Digitizer – Step Scan (When VIVID 900/910 is Selected)

n

When Using the Bench Top Frame Set

M

emo

The VIVID 910 or VIVID 900 can be mounted on the bench top frame set vertically or horizontally.
For the mounting method, refer to the instruction manual of the frame set.
Saving the calibration chart data helps you reduce work time when scanning different objects under the same conditions.

Operating Procedure

1

From the [File] menu, select [Import],

[Digitizer] and then [Step Scan].

The [File-Import-Digitizer-Step Scan] dialog
box will appear.

• The monochrome monitor image currently cap-

tured by the VIVID 910 or VIVID 900 will ap-
pear in the image area of the dialog box.

3

Place the object on the rotating stage.

Note

If the VIVID digitizer is mounted on the frame set hori-
zontally, the object will be affected by repeated reflection
on the rotating stage surface, preventing correct scan
operation. To prevent this, place an appropriate item of
the following thickness under the object to raise it.

Measurement Distance

Thickness of Item

600 mm

Approx. 30 mm

1000 mm

Approx. 20 mm

4

To display the object in the middle of

the image area, change the position of
the object or move the instrument back
and forth to change the view angle.

M

emo

If necessary, replace the lens attached to the VIVID
digitizer.

2

Select the desired installation direction

of the VIVID digitizer.

From the [Hardware] tab, check the [Bench
Top Frame set] checkbox, and select the VIVID
digitizer installation direction by clicking the
corresponding [Mounted] radio button.
Select [Vertical] if the VIVID 910 or VIVID 900 is
mounted vertically, or select [Horizontal] if it is
mounted horizontally.

M

emo

If the VIVID digitizer is mounted horizontally, the pre-
view image will be in portrait form.
After the image is converted to 3D, it will be displayed
according to the coordinate system of the VIVID.

Advertising