Kamera Werk Dresden CMOS User Manual

Page 17

Advertising
background image

Manual: CMOS Industrial Camera LOGLUX

i5

Version 1.08 (04/07)



KAMERA WERK DRESDEN GmbH

Page 17 of 46

The user profile parameters

The 'Region of Interest' profile menu

This menu is used for adjusting the image
region (on the sensor) which is of interest to
the user (region of interest), and for directly
setting the maximum possible frame readout
rate by means of the parameters X_Size (width
of the ROI) and Y_Size (height of the ROI)
since sensor pixels are scanned in the
specified region only (progressive scan).

The horizontal image geometry parameters
'distance of ROI from left' and 'width of the ROI'
are set in the 'Left' and 'Width' fields,
respectively. The associated scroll bars can
also be used for a coarse pre-adjustment. Only
integer values may be set.
The vertical image geometry parameters
'distance of ROI from top' and 'height of the
ROI' are set in the 'Top' and 'Height' fields,
respectively. The associated scroll bars can
also be used for a coarse pre-adjustment.
The maximum possible values of 'distance of
ROI from left' and 'distance of ROI from top' are
limited by the parameter settings 'width of the
ROI' and 'height of the ROI'.
The graphic 'ROI position' display gives an
indication of the position and size of the ROI
set relative to the full CMOS sensor area.

Figure 13 : The 'Region of Interest' profile menu

Advertising