I5 cl camera – Kamera Werk Dresden CMOS User Manual

Page 46

Advertising
background image

Version 1.08 (04/07)

Manual: CMOS Industrial Camera LOGLUX

i5



Page 46 of 46

KAMERA WERK DRESDEN GmbH

InterfaceLibrary: This is the name of the serial dynamic link library 'clser*.dll' of your

framegrabber. If the library is not located in the installation folder of the configuration tool, the
whole directory path must be specified.

MinPortId: This is the lowest supported CameraLink

port (tap) identifier; see the framegrabber

manual.

MaxPortId: This is the highest supported CameraLink

port (tap) identifier, see the framegrabber

manual.

Description: This is a freely chosen descriptor of the framegrabber used for identification

purposes in the LuxWare configuration tool.

Example (CameraLink

framegrabber MVtitan-CL made by Matrix Vision):

[GenericCameraLinkDevice]
InterfaceLibrary=clsermv.dll
MinPortId=0
MaxPortId=1
Description=MVTitan_CL

Using software-supported framegrabbers on the serial COM port of the
LOGLUX

i5 CL camera

For a very safe and very fast communication between the host system (PC/IPC) and camera, the
serial COM port of the LOGLUX

i5 CL camera is recommended to be used. However, it is a

prerequisite that the CameraLink

framegrabber is supported by the LuxWare configuration tool.

An additional 9-pole null modem cable (RS-232 port of the split adapter cable) is here required to
connect the camera to a vacant RS-232 (COM) port of the host system (PC/IPC).
Furthermore, the INI file 'LuxConfig.ini', which is found in the same directory as the configuration
software, needs to be modified as follows (with a simple text editor), and the following lines have to be
added:

[PortMapping]
<Grabber>Tap<Id>=<COM-Port>

Explanation:

Grabber stands for one of the supported framegrabbers.

Tap<Id> stands for the used framegrabber CameraLink

port (on the MVtitan-CL of Fa. Matrix

Vision this is, for example, '0' or '1').

COM port stands for the used RS-232 (COM) port of the host system (PC/IPC).

Example (CameraLink

port 1 of the MVtitan-CL is 'mapped' with the COM1 port):

[PortMapping]
MVTitanCLTap1=1

Advertising