The ‚sensor‘ profile menu – Kamera Werk Dresden CMOS User Manual

Page 21

Advertising
background image

Manual: CMOS Industrial Camera LOGLUX

i5

Version 1.08 (04/07)



KAMERA WERK DRESDEN GmbH

Page 21 of 46

The ‚Sensor‘ profile menu

Sensor-specific parameters are entered in this menu. These include the pixel clock rate, the shutter
mode, the ADC amplification, and the gamma correction option.

The pixel clock rate of the camera can be set in
the 'Pixel clock' box. The frame readout time is
displayed below the box.
One of the two sensor shutter modes, i.e.
synchronous shutter or rolling shutter, can be
selected under 'Shutter'.
Under 'Amplification' the user can set the
amplification factor for the analog amplifier
downstream of the sensor in 6 increments.
Default is 1.

Note:

For

the

following

reasons,

the

amplification factor should not be changed in
industrial image processing applications:

The proper calibration of the camera is no

longer guaranteed.

The pixel values are falsified through the

amplification limitation.

The signal noise would be amplified and the

desired improvement of the image brightness
cannot be achieved.

Figure 17 : The ‚Sensor‘ profile menu