Function group ‚working parameters – Kamera Werk Dresden CMOS User Manual

Page 36

Advertising
background image

Version 1.08 (04/07)

Manual: CMOS Industrial Camera LOGLUX

i5



Page 36 of 46

KAMERA WERK DRESDEN GmbH

Example:

w $14C #1

;permanent precharging

PROFILE_DESCRIPTION

The register contains a string of 32 ASCII characters that identify the profile.

Function group ‚Working parameters‘

This function group provides various camera service registers, among them registers specifying the
firmware of the camera as well as functions for setting the trigger register, for initializing and copying
camera profiles, and for reading a temperature sensor inside the camera. Please note that these
registers are volatile, i.e. the register values are not saved when the power is turned off.

Register

Address

Format

Description

Value range

Meaning

Access

PARAM_VERSION

$900

1 long

Firmware version

read only

PARAM_EVENT

$904

1 byte

Event generation for trigger
and switchport

$01
$02
$04

Write access releases a trigger
signal, switchport 1 event or
switchport 2 event

write

only

PARAM_INITPROFILE

$905

1 byte

Initializes a profile

$1x ... 4x

$x1
$x2
$x3

Initializes profile 1 ... 4 with the
Init values for
Single integration slope mode
Dual integration slope mode
Quadr. integration slope mode

write

only

PARAM_COPYPROFIL

$906

1 byte

Copies a profile

$1x ... $8x
$x1 ... $x8

Target profile 1 ... 4
Source profile 1 ... 4

write

only

PARAM_TEMP0

$908

1 word

Temperature sensor 0

218 .. 398

Temperature in [Kelvin]

read only

PARAM_TEMP1

$90A

1 word

Temperature sensor 1

218 .. 398

Temperature in [Kelvin]

read only

Table 6 : Registers of function group 'Working parameters'

PARAM_VERSION

This register allows the camera to be identified from the host register.

PARAM_EVENT

Events can be generated in the camera by entering data in this register.
These events are sent to various modules such as the trigger or switchport
module. Functions can be triggered in the respective module if the event
register had been specified in the module's event source parameter. Example:
If the value $04 (event register) had been entered in register
PROFILE_TRGSOURCE, a write access to register PARAM_EVENT using
the value $01 will trigger a framegrabbing process. This could be done to
simulate the response of the camera to an external trigger signal.

PARAM_INITPROFILE

The register permits the factory (default) settings of camera profiles 1 to 4 to
be reset. The register content of the respective target profile will be irrevocably
overwritten by the register content of the source profile.

Example:

w $905 $13

;initializes P1 with P3

PARAM_COPYPROFILE

The register permits camera profiles 1 to 8 to be given identical register
contents. The register content of the respective target profile will be
irrevocably overwritten by the register content of the source profile.

Example:

w $906 $62

;copies Profil2 to Profil6