background image

Table 6. System-board jumpers

Jumper
number

Jumper
name

Jumper setting

1

JP6

UEFI boot
recovery

v

Pins 1 and 2: Normal operation (default).

v

Pins 2 and 3: Enable the UEFI recovery mode.

2

JP1

CMOS
clear

v

Pins 1 and 2: Normal operation (default).

v

Pins 2 and 3: Clears CMOS.

3

SW6

switch
block

Note: If no jumper is present, the server responds as if the pins are set to 1
and 2.

Table 7. System-board switch 6

SW 6 Switches

Switch description

1

Reserved (Default off)

2

Power-on password override when on. (Default off)

3

Reserved (Default off)

4

When off, this loads the primary IMM firmware ROM page. When on, this loads the secondary
(backup) IMM firmware ROM page. (Default off)

Notes:

1. Before you change any switch settings or move any jumpers, turn off the server;

then, disconnect all power cords and external cables. (Review the information in
Chapter 2, “Safety information,” on page 5).

2. Any system-board switch or jumper blocks that are not shown in the illustrations

in this document are reserved.