Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

The System %1 encountered a
POST Error.
(%1 = CIM_ComputerSystem.
ElementName)

Error

A POST error has occurred.
(Sensor = Firmware Error)

1. Update the server firmware

on the primary page.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

2. (Trained service technician

only) Replace the system
board.

A Uncorrectable Bus Error has
occurred on system %1.
(%1 = CIM_ComputerSystem.
ElementName)

Error

A bus uncorrectable error
has occurred.
(Sensor = Critical Int PCI)

1. Check the system-event log.

2. Check the PCI error LEDs.

3. Remove the adapter from the

indicated PCI slot.

4. Check for a server firmware

update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

5. (Trained service technician

only) Replace the system
board.

44

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual