Installing a microprocessor retention module

To install a microprocessor retention module, complete the following steps:

1. Orient the triangle-shaped indicator on one corner of the microprocessor

retention module to the corresponding alignment triangle on the system board;
then, place the retention module on the system board.

2. Using a T8 Torx screwdriver, install the four screws that secure the module to

the system board.

3. Install the microprocessor and heat sink (see “Installing a microprocessor and

heat sink” on page 220).

Attention:

Make sure that you install each heat sink with its paired

microprocessor.

4. Install the air baffle (see “Installing the air baffle” on page 170).

5. Return the power-supply cage to its closed position (see “Closing the

power-supply cage” on page 160).

6. Install the power supplies (see “Installing a hot-swap power supply” on page

175).

7. Install and lock the left-side cover (see “Installing the left-side cover” on page

158).

8. Reconnect the external cables and power cords; then, turn on the attached

devices and turn on the server.

230

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual