Installing a heat-sink retention module – Lenovo THINKSERVER 3821 User Manual

Page 236

Advertising
background image

Installing a heat-sink retention module

1

Alignment triangle

To install a heat-sink retention module, complete the following steps:

1. Place the heat-sink retention module in the microprocessor location on the

system board.

2. Using a Phillips screwdriver, install the four screws that secure the module to

the system board.

3. Install the heat sink (see “Installing a microprocessor and heat sink” on page

220).

Attention:

Make sure that you install each heat sink with its paired

microprocessor.

4. Install the air baffle (see “Installing the air baffle” on page 170).

5. Return the power-supply cage to its closed position (see “Closing the

power-supply cage” on page 160).

6. Install the power supplies (see “Installing a hot-swap power supply” on page

175).

7. Install and lock the left-side cover (see “Installing the left-side cover” on page

158).

8. Reconnect the external cables and power cords; then, turn on the attached

devices and turn on the server.

228

ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual

Advertising
This manual is related to the following products: