Installing a hot-swap power supply – Lenovo TS100 User Manual

Page 101

Advertising
background image

Installing a hot-swap power supply

This procedure applies only to server models that have hot-swap power supplies.
See “Installing a non-hot-swap power supply” on page 117 for information about the
installation of a non-hot-swap power supply.

To install a hot-swap power supply, complete the following steps:

1. Place the power supply into the bay guides.

1 Release lever
2 Hot-swap power supply

2. Using the handle, push the power supply toward the front of the chassis until it

locks into place.

3. Connect one end of the power cord into the connector on the back of the power

supply and connect the other end of the power cord into a properly grounded
electrical outlet.

4. Make sure that both the ac and dc power LEDs on the rear of the power supply

are lit, indicating that the power supply is operating correctly.

Chapter 4. Removing and replacing server components

83

Advertising
This manual is related to the following products: