Installing a non-hot-swap power supply – Lenovo TS100 User Manual

Page 135

Advertising
background image

Installing a non-hot-swap power supply

This procedure applies only to server models that have a non-hot-swap power
supply. See “Installing a hot-swap power supply” on page 83 for information about
the installation of a hot-swap power supply.

To install a non-hot-swap power supply, complete the following steps:

1. Position the power supply in the chassis so that the screw holes in the power

supply are aligned with the corresponding holes in the rear of the chassis.

2. Install the four screws that secure the power supply to the chassis.

3. Connect the cables from the power supply to the system board and all internal

components.

4. Install the side cover (see “Installing the side cover” on page 63).

5. Lock the side cover if you unlocked it during removal.

6. Reconnect the external cables and power cords; then, turn on the attached

devices and turn on the server.

Chapter 4. Removing and replacing server components

117

Advertising
This manual is related to the following products: