Lennox Hearth Montage 32FS User Manual

Page 10

Advertising
background image

10

VENTING REQUIREMENTS

It is recommended that only an Lennox Hearth Products dealer install your

pellet stove. The specified installation requirements must be followed to

ensure conformity with both the safety listing of the appliance and local

building codes. All clearances, installation instructions and precautions

specified by the vent manufacturer must be followed.
Selecting a Location
Review the appliance clearance requirements before installing the

venting system (see Page 5). Position the appliance far enough away

from walls to allow adequate room for servicing. Choose the appliance

location with the least amount of interference with the house framing,

plumbing, wiring, etc.
Preferred Vent Configuration
For the best performance, we recommend a vent run design which runs

vertically and terminates above the roof line. This design will allow natural

draft to improve the flow of flue gases and will aid in combustion and

stove performance.
Note: 30 feet maximum vertical vent allowed (6 inches minimum verti-

cal).
Type of Pipe

This stove requires type “PL” vent pipe (pellet vent pipe, sometimes

referred to as “L-Vent pellet vent”), listed to UL 641 or ULC S609. Con-

nect the pellet vent pipe or the “tee” to the flue collar using a minimum

of three screws and seal as specified in “Pipe/Liner Joint Requirements”

on this Page. Do not use class B gas chimney or single wall chimney

as a substitute.
Size of Pipe
These pellet stoves are approved for use with the following vent sizes: 3”

(75 mm) standard, or 4” (100 mm), see Page 13 - for determining correct

size vent). When 4” pipe is used: for horizontal vent installations use a 3”

(75 mm) to 4” (100 mm) adapter - available from vent manufacturer. For

vertical installations use a 3” (75 mm) to 4” (100 mm) “tee” - available

from vent manufacturer.
Offsets
In every installation, a single or double clean-out “tee” is recommended

for every ninety-degree offset (this tee will help collect ash residue and

will allow for routine cleaning without the need to disconnect sections

of pipe).
Pipe Clearances/Requirements
See pipe manufacturers instructions for installation of venting components

and clearances. Follow pipe manufacturers installation precautions for

passing pipe through a combustible wall or ceiling (i.e. use an approved

thimble).

Notes

• Offsets and horizontal runs accumulate fly-ash and soot which reduces

the exhaust flow and performance of the stove.

• Total Offsets in venting system should not exceed 270° total in direc-

tion change.

• Maximum Vertical Vent - 30 feet (9.14 M)

• Horizontal Runs - The maximum total horizontal run must not exceed

10 feet (3.1 meters).

• Horizontal run of pipe requires 1/4” (7 mm) rise per foot.

• Pellet vent pipe requires 3” (75 mm) clearance from outside of pipe

unless otherwise specified by vent manufacturer - all diameters: 3” (75

mm) and 4” (100 mm). A support bracket must be installed every 4

feet (1.2 m) of pellet vent pipe on the exterior wall of the house unless

otherwise specified by vent manufacturer.

• It is not recommended to terminate exhaust vent on the prevailing wind

side of the house.

• It is not recommended using a termination cap with a screen (fly-ash

can collect in a screen resulting in blockage).

Pipe/Liner Joint Requirements
Silicone sealant and 3 screws are required to secure the first vent con-

nection to the appliance flue collar. Seal the remaining vent sections per

the vent manufacturers instructions and secure all sections with 3 screws

minimum per section. ALL horizontal joints must be sealed gas-tight (air

tight, sealed connection). Use RTV high temperature silicone or Interam,

if necessary, to provide a complete seal between vent sections.
Connection to Masonry Chimney through a Wall
Be sure to verify the construction of a masonry chimney, as it may have

combustible framing.
Approved liner when relining Masonry or Factory-Built Fireplaces is

2100HT (degree F.) liner listed to UL 1777 or ULC S635.
Connection to an Existing Class A Chimney
A chimney adapter can be used to make the connection from 3” (75

mm) or 4” (100 mm) pellet vent pipe (listed to UL 641 or ULC S609) to

existing UL chimney system. Verify with the pipe manufacturer that your

pipe brands will interconnect.
Horizontal Vent Installations
On all horizontal vent installations (short, horizontal runs with no vertical

pipe); care should be taken when choosing a location for terminating the

vent. It is not recommended to directly vent the exhaust on the prevail-

ing wind side of the house. It is recommended that when an appliance

is vented directly through a wall, a minimum of 8 feet (2.5 m) of vertical

pipe should be installed to create some natural draft. This will reduce

the possibility of smoke or odor entering the dwelling during appliance

shutdown or loss of power.
Vent Termination
Do not terminate vent in an enclosed or semi-enclosed area such as:

carports, garage, attic, crawl space, under a deck, porch, narrow walkway,

closely fenced area, or any location that can build up a concentration of

fumes such as a stairwell, covered breezeway etc.
Vent surfaces can get hot enough to cause burns if touched. Adults

should supervise children when they are in the area of a hot stove.

Non-combustible shielding or guards may be required.
Termination Cap
The termination of the outside chimney of the pellet stove shall be located

in accordance with the following:

A. Higher than 3 feet (.92 m) above any forced air inlet (air conditioner,

etc.) located within 10 feet (3 m).

B. Not less than 4 feet (1.2 m) below, 4 feet (1.2 m) horizontally from or

1 foot (3.1 m) above any gravity air inlet (door, window, etc.) which

flue gases could reenter the dwelling.

C. Not less than 2 feet (.6 m) from combustible materials such as an

adjacent buildings, fences, protruding parts of the structure, roof

overhang, plants and shrubs, etc. and not less than 7 feet (2.1 m)

above grade when located adjacent to the public sidewalks (access).

The final termination of the exhaust system must be configured so that

flue gases do not jeopardize the safety of people passing by, overheat

combustible portions of nearby structures or enter the dwelling.

D. Not less than 3 feet (.92 m) below an eave (maximum overhang of 3

feet (.92 m) or any construction that projects more than 2” (51 mm)

from the plane of the wall.

E. The distance from the bottom of termination to grade is 12” (305 mm)

minimum. This is conditional upon plants and nature of grade surface: Be

careful to choose a location for the vent termination which does not expose

people or shrubs to high heat from the exhaust gases. The exhaust gases

are not hot enough to ignite grass, plants and shrubs located in the vicinity

of the termination although they should be a minimum of 3 feet (.92 m)

away. The grade surface under the termination must not be a lawn.

F. Since sparks may escape from the exhaust pipe of any stove, use

caution when positioning the vent pipe. Refer to pipe manufacturer’s

instructions when installing and terminating the exhaust. The vent pipe

should be horizontal and never run the pipe in a downward direction

(recommend a 1/4” [7 mm] rise per foot horizontal).

Silicone sealant and 3 screws are required to secure the first vent connection to the appliance flue collar. Seal the remaining vent sections per the vent

manufacturers instructions and secure all sections with 3 screws minimum per section. ALL horizontal joints must be sealed gas-tight (air tight, sealed

connection). Use RTV high temperature silicone or Interam, if necessary, to provide a complete seal between vent sections.