Lennox Hearth Montage 32FS User Manual

Page 11

Advertising
background image

11

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Vent Termination Locations

A = Clearance above grade, veranda, porch, deck, or bal-

cony (min. 12”/30cm)

B = Clearance to window or door that may be opened (min.

12”/30cm above - 48”/1.2m below and to the side)

C = Clearance to permanently closed window *(min.

12”/30cm)

D = Vertical clearance to ventilated soffit located above

the terminal within a horizontal distance of *(min.

24”/60cm) from the centerline of the terminal (min.

22”/55cm) check with local code.

E = Clearance to unventilated soffit *(min. 12”/30cm)

F = Clearance to outside corner *(min. 12”/30cm)

G = Clearance to inside corner *(min. 12”/30cm)

H = Not to be installed above a meter/regulator assembly

within *(min. 36”/90cm) horizontally from the center-

line of the regulator.

J = Clearance to service regulator vent outlet *(min.

72”/1.8m)

K = Clearance to non-mechanical air supply inlet to build-

ing or the combustion air inlet to any other appliance

*(min. 48”/1.2m)

L = Clearance to a mechanical air supply inlet *(min.

120”/3.1m)

M = **Clearance above paved sidewalk or a paved driveway

located on public property *(min. 84”/2.1m)

N = ***Clearance under veranda, porch, deck, or balcony

(min. 12”/30cm)

Note:

* Local codes or regulations may require different clear-

ances.

** A vent shall not terminate directly above a sidewalk or

paved driveway which is located between two single

family dwellings and serves both dwellings.

*** Only permitted if veranda, porch, deck, or balcony is

fully open on a minimum of two sides beneath the

floor.

Vent Terminal
Area Where Terminal Is Not Permitted

(From Eave)

Vertical Terminal

Vertical Terminal

Fixed Closed

Able To Open

A

A

B

B

B

B

C

D

E

F

G

H

J

K

L

M

N

24”

(610mm)

B

Air Supply Inlet

24”

(610mm)

Figure 9