7

• Air Wash

A small slot in the door that allows room air to be pulled into the

firebox and pours over the inside surface of the door glass to inhibit

the build up of soot.

• Auger

A motor powered screw device that transfers the fuel from the hopper

to the feed chute to deliver pellets to the UltraGrate™.

• Auger Motor

Drives the Auger. Motor specifications are: 0.5 Amp, 1.25 RPM

(revolutions per minute).

• Blower, Room Air (Convection)

The blower function is to transfer the heat from the appliance to heat

the room air.

• Blower, Exhaust (Combustion)

It has a radial impeller to deliver more air to the UltraGrate™. It pulls

air into the UltraGrate by creating a negative pressure. This is done

by extracting the exhaust gases out of the firebox and pushing the

exhaust downstream to the flue exit.

• Thermal Switches, High Limit

There are three of these high-limit thermal switches on this model.

If a temperature reaches the high limit temperature, the reset switch

will “trip” and stop the flow of electricity to the auger motor. The

thermal switches will not reset until they have cooled below low reset

temperature).

- Auto Reset Thermal Snap Switch for Room Air Blower (L50-

30F, N/C*) – This switch will trip at 250° F and will automatically

reset when it reaches a temperature of 220° F. This switch is

located on the room air blower jacket and is designed to detect

an overfire condition.

- Auto Reset Thermal Snap Switch for Combustion Air Inlet

(L50-30F, N/C*) This switch will trip at 250° F and will auto-

matically reset when it reaches a temperature of 220° F. This

switch is designed to detect reversed flow or excessive heat

in the ashpan area. This switch is located on the firebox base

behind the convection jacket, directly above the ashpan. This

switch is most easily accessed by removing the ashpan

- Manual Reset Thermal Snap Switch for Feed Chute (L300-145F,

N/C*) This switch will trip at 300° F and will not be resettable

until it reaches a temperature of 155° F. This switch is designed

to detect if heat from the fire is approaching a path toward the

hopper. If this switch trips it must be manually reset. To reset,

open left side access door (facing stove), locate switch on the

side of the auger tube and press the red button in the center until

it clicks into the reset position.

Thermal Switch, Low Limit (Ceramic, F140-0F, N/O*) - This "proof

of fire" switch will close at 140° F and will not open until it reaches

a temperature of 120° F. This switch is located on the combustion

blower (behind the right side panel). It is designed to shut down the

stove (auger motor and both blowers) if it does not detect the heat of

a fire at the end of the initial startup period.

• Hopper Lid Switch

It is located on the left hinge area inside the hopper. It detects whether

the hopper lid is open and will turn off the auger motor if the hopper

lid is not properly closed. When opening the hopper when refueling,

do not allow the hopper lid to remain open too long or the fire may

extinguish. NEVER DISCONNECT OR BYPASS THIS SWITCH FOR

ANY REASON.

Hopper

The hopper is where the pellets are stored.

• Heat Output Button

It controls power to the feed system - auger motor and combustion

blower. Use the heat output button to adjust to any of the five feed

rate settings (which controls the burn rate).

• Pressure Switch

A safety device used to shut off the feed system (auger motor) if there

is too much back pressure in venting system. Some possible causes

are as follows:

• The venting system is obstructed.

• High altitude or other misc. environmental conditions affecting

exhaust flow.

• Improper venting system.

The Pressure Switch is located inside the right access door right next

to the combustion blower.

UltraGrate (Burn Grate)

This is where combustion occurs and may be referred to as the “Burn

Grate”.

* N/C = Normally Closed

N/O = Normally Open

Figure 35 - WIRING DIAGRAM 120 V AC

COMPONENT DEFINITIONS

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

MATERIAL SPECIFICATIONS:

MATERIAL - WHITE POLYESTER 740 2. MIL PRINT TREATED
ADHESIVE - PERMANENT ACRYLIC ADHESIVE
MATERIAL SIZE – 4” X 10”
TEXT – BLACK
DIELINE WILL NOT PRINT

SUPPLIER:

INTERNATIONAL GRAPHICS & NAMEPLATE, INC.
14413 NE 10TH AVE., SU. C
VANCOUVER, WA 98685
800-458-3355

REV

DATE

ALTERATIONS

PREPARED BY /

& CHKR

NC

06/04/2008 T-3654 New Release

MSJ / JB / JSH / CRZ

TOLERANCE UNLESS OTHERWISE NOTED LINEAL DIM. SQUARENESS, NOTCH u BRAKE RES. +/- 1/32, ANGLES +/- 2°, HOLES

UP TO 1/4” +/- .004, 1/4” +/- .005, 1/4” TO 1” +/- .010, OVER 1” +/- 1/64”

Lennox Hearth Products ENGINEERING DEPT.

Orange, California

DESCRIPTION:

WIRE DIAGRAM LABEL - MONTAGE 32FS

FOR FINISH SPECS REFER TO ES-0049

PAINT

NONE

INSIDE

SHEET NO. DWG.

1 OF 1 NO.

537039-01

PAINT

NONE

OUTSIDE

THIS PRINT IS THE PROPERTY OF LENNOX HEARTH PRODUCTS

PAGE 1 OF 1

DO NOT SCALE THIS PRINT

2-BLK

5-WHT

HOT
GND

NEUT

GRN

CONV

BLOWER

3-BLK

AUGER

MOTOR

IGNITER FUSE

IGNITER

L

N

1-BLU

4-ORG

2-BLK

J P

J P

COMB

BLOWER

THERMOS

TA

T

CONNECTOR

YEL

YEL

HI-LIMIT

AUTO-RESET

SWITCH N/C

HI-LIMIT

AUTO-RESET

SWITCH N/C

PRESSURE

SWITCH

N/C

HOPPER

LID SWITCH

N/C

HI-LIMIT MANUAL

RESETTABLE

SWITCH N/C

LO-LIMIT AUTO-RESET SWITCH N/O

ON COMBUSTION BLOWER HOUSING

NOTE: SWITCH CONDITIONS

GIVEN AT ROOM TEMPERATURE,

STOVE OFF

N/C = NORMALLY CLOSED

N/O = NORMALLY OPEN

= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION

POWER DISCONNECT

1-BLU

3-RED

1-BLU

P/N 537039-01 Rev. NC

Montage

TM

32FS

Wire Diagram

2

4

6

1

3

5

J = JACK

P = PLUG

ON AUGER

TUBE

LEFT HOPPER

LID HINGE

AREA

INSIDE RIGHT

ACCESS DOOR

1

3

2

4

6-BRN

ABOVE ROOM

AIR BLOWER

DIRECTLY

ABOVE

ASHPAN

2-BLK

IGN 08-2302