6

Flue Size

3” (76 mm) Rear

Floor Protection

Front and Sides: 6”(15 mm)

Requirements

Back: Up to 6”(15 mm)

u

Hopper Capacity

55 Lbs.

v

Burn time

15 - 37 hours

v

Fuse, Control Board

5 Amp, 50 volt, 3AG

w

Fuse, Igniter

6 Amp, 15 volt

w

Heat Input

13,000 - 3,000 BTU/hr

v

(BTU’s per hour)

Emissions

< 4.5 gr/hr (varies w/size and

type of fuel) EPA Certified

v

Convection (room air)
Blower

150 CFM; 1.5 Amps,

175 rpm

Combustion Blower

95 CFM: 1.0 Amps,

3000 rpm

Auger Motor

1.5 RPM; 0.5 Amps

Standard Features

Fastfire Self Igniter

Wall Thermostat

(wire included)

SPECIFICATIONS - Montage™ 3FS

Notes:
• Dimensions shown are approximations only

.25

(+/- 1/4”)

• Approved for Manufactured Home Installations.

Optional Kits Available - Decorative trim kits, log

set, window screen and 4” Quick Disconnect
kits.

• The burn grate is designed with advanced

UltraGrate™ technology.

u

Non-combustible floor protection is required

(see Floor Protection, Page 4). When installed
at clearances less than 6”, the floor protector is
only required to extend to the wall.

v

Fuel delivery and burn times will vary depending

on size and type of fuel used. Estimated heat input
based on fuel value of 8400 BTU per lb.

w

Fuses are rated as fast blow.

Product Reference Information

Cat. No.

Model

Ship.

Weight

Ship.

Volume

H6839

Montage 3FS

85 lb.

.06 cu. ft.

9-5/8”

245mm

28-11/16”

729mm

9-3/16”

233mm

24-11/16”

627mm

1-9/16”

40mm

11-1/4”

286mm

23-1/8”

507mm

2-15/16”

75mm

5-1/2”

140mm

11-1/4”

286mm

7”

178mm

22-1/2”

572mm

2”

51mm

Stove Back

Clean-Out

Tee

5-7/8"