Lennox Hearth Montage 32FS User Manual

Page 20

Advertising
background image

0

Turning Off Your Stove

Press the "STOP" button to initiate the shut down cycle (auger LED will

be red). The pellets will stop feeding and the blowers will continue to

run on a timed cycle. The stove will shut down safely upon completion

of the shut down cycle.

Shutdown Mode - When the thermostat opens (not calling for heat),

or the auger "STOP" button is pressed (feeding LED will be off), power

to auger motor will be discontinued. The blowers will continue at the

control board setting until the low limit thermal switch cools enough

(below 120° F) to open. For safety, the blowers will continue to run

for approximately 10 minutes before the unit shuts down.

Damper Operation

The damper assembly controls the amount of combustion air that is

delivered to the firebox. With the damper adjusted all the way in, the

airflow will be at its minimum. As the damper is moved outward, more

air is delivered (see Damper Location and Adjustment on Page 9).

It will be necessary to monitor the appearance of the flame during the first

4-8 bags of pellets. If the flame is smoky red or orange with evidence of

soot at the top of the flame, the damper will need to be adjusted to deliver

more combustion air (see Damper Location and Adjustment on Page 9).

If the flame is “short” at the higher burn rates, or if the pellets are burning

up in the UltraGrate™ before new pellets are fed into the fire, the damper

may need to be adjusted to deliver less combustion air.

After the damper is adjusted, re-evaluate the appearance of the flame. It

may be necessary to continue adjusting the damper in increments until

proper combustion is achieved (the flame should become yellow and

begin to “dance”).

Once the damper has been properly set (and if the routine maintenance

is performed as needed), the damper should not require re-adjustment

unless you are changing from a premium grade pellet to a standard or

high ash pellet, in which case the damper may need to be moved outward

to help prevent the accumulation of ash in the UltraGrate.

Damper Adjustment Guideline

Lack of Combustion Air:

By opening the damper, this will increase combustion air delivery. Symp-

toms of insufficient combustion air include; unburned fuel, lazy smoky or

red / orange flame, excessive ash or soot, excessive buildup on glass.

Contributing factors:

• High Altitude – Lack of oxygen

• Restrictive Venting (elbows, horizontal runs, cold external chimneys,

etc.)

• Dirty / Poor Quality Fuel

• Lack of Maintenance

Note: Excessive amounts of fly-ash built-up in the UltraGrate™, clinkers

in the UltraGrate or leakage of air (if the grate is not properly seated) will

starve the fire for air. See Routine Maintenance, on Pages 21 through 24

for information on cleaning requirements.

Excessive Combustion Air:

Adjusting the damper to a more closed position will reduce the combustion

air delivery. Symptoms of excessive air include; fuel burns too quickly

(results in smoking or smoldering pellets), white to yellow flame, etc. If

the damper is open too far, the burning pellets will lift off the grate and

fly up into the air much like popping corn does.

Note: Excessive combustion air reduces efficiency.

Contributing factor:

• Venting system providing excessive draft.

Correct Combustion Air / Proper Burn Characteristics:

When the damper is correctly set, the burning pellets should move (wiggle)

around slightly and the flame should be bright yellow.

Automatic Safety Features

Power Outage:

During a power outage, the stove will shut down safely. The stove will

automatically restart when power is resumed. The solid state control

board has an internal memory that will retain heat output and blower

speed settings through voltage interruptions.

A small amount of smoke may leak from the top of the window glass,

the hopper and from the combustion air intake, if the stove is vented

horizontally with no vertical pipe. This will not persist for more than 3

to 5 minutes and will not be a safety hazard. It may set off your smoke

alarm.

Note: If the area in which you live is prone to frequent power outages, it

is recommended that a minimum of 8 feet (2-1/2 meters) of vertical vent

pipe be included in a free-standing installation to induce a natural draft

in the event of a power failure.

Overheating:

High temperature thermal switches will automatically shut down the stove

if it overheats. Allow up to 45 minutes cooling time before re-lighting. Keep

enough convection air going through stove to keep it cooling properly

(adjust convection [room air] blower speed to a higher setting), this will

ensure long life of the stove. If the overheating continues, contact your

Lennox Hearth Products dealer for more information.

Advertising