NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Determining Size Of Pipe To Install

To determine what diameter pipe to use in an installation (3” or 4”), first

find the “equivalent pipe length” using the following guidelines, then plot

this number and the altitude on the chart (Figure 13).

Fill out the installation chart, and calculate your total equivalent pipe

length. After you have the total equivalent pipe length, use the Pipe

Selection Chart below to determine if your installation requires 3” or 4”

exhaust pipe.

Installation Chart

4 “ Diameter Only

3 or 4”

Diameter

Altitude x 1000 Feet

Eq

ui

va

le

nt

P

ip

e

Le

ng

th

(F

ee

t)

30

0

10

0

0

1



3

4

5

6

7

8

9

10

Figure 13

- Pipe Selection Chart

A

E

F

H

G

B

C

D

Figure 14

- See Sample Installation Chart

A - 90 Degree Elbow

B - 1’ Horizontal Pipe

C - 45 Degree Elbow

D - Standoff Braces

E - 8’ Vertical Pipe

F - ’ Horizontal Pipe

G - 90 Degree Tee

H - Wall Thimble

NOTE: All equivalent pipe styles

shown for model Montage 32FS.

Type of Pipe

# of Elbows or

Feet of pipe

Equivalent Feet

Total Equivalent

Feet

90° Elbows/

Tee (A & G)

x

5 Feet (1.5 m)

45° Elbows

(C)

x

3 Feet (1 m)

Horizontal

(B & F)

x

1 Feet (.3 m)

Vertical (E)

x

.5 Feet (.15 m)

Table 3

Sample Installation Chart

Type of Pipe

# of Elbows or

Feet of pipe

Equivalent Feet

Total Equivalent

Feet

90° Elbows/

Tee (A & G)



x

5 Feet (1.5 m)

10 (3 m)

45° Elbows

(C)

1

x

3 Feet (1 m)

3 (1 m)

Horizontal

(B & F)

3

x

1 Feet (.3 m)

3 (1 m)

Vertical (E)

8

x

.5 Feet (.15 m)

4 (1. m)

Table 4

- Sample Chart for Figure 14

Advertising