NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

5

Up to * 6” (153 mm)

6”

(153 mm)

min.

6”

(153 mm)

min.

6” (153 mm)

min.

Figure 1 -

Floor Protection Requirements

*Note: When installed at clearances less than 6”, the floor

protection is only required to extend to the wall.

Rear

Front

Top View

Floor Protector

Standard residential or manufactured home installation. These appliances

require the following minimum clearances to combustibles:

Minimum Clearances To Combustibles

Figure 2

Combustible

Combustible

Montage 3FS

Horizontal Flue –

Directly Through Wall

Interior Vertical

Flue

A - Side wall to unit

u

4” (10 mm)

u

4” (10 mm)

B - Back wall to unit

” (51 mm)

9” (9 mm)

C - Side wall to unit Corner 1” (5 mm)

1” (5 mm)

D - Max. Depth of Alcove

v

4” (610 mm)

v

4” (610 mm)

E - Flue to Wall

3” (77 mm)

3” (77 mm)

u

Measured to fuel hopper lid in alcove.

v

Minimum Alcove Measurements - Height 48” (10 mm) x Width 31”

(788 mm) x Maximum Depth 4” (610 mm)

Table 1 -

Minimum Clearances To Combustibles

Combustible

Rear Wall or Alcove

Figure 3

Corner

B

A

E

D

A

E

C

C

Combustible

Combustible

IMPORTANT

• Minimum clearances specified may not allow

for ease of operation and maintenance (please

take this in to account when planning the instal-

lation). If installed to the minimum clearances,

removal of the appliance may be necessary for

servicing.

• Recommended clearance zone from the front

of the appliance to combustibles is 4 feet mini-

mum.

• Clearances to combustibles for the appliance

can only be reduced by means approved by the

regulatory authority.

CLEARANCES

FPO

FPO