Lennox Hearth Montage 32FS User Manual

Page 6

Advertising
background image

6

INSTALLATION TIPS

GOOD INSTALLATION:

Horizontal Installation

(Direct Vent - Outside Wall)

No natural draft. Wind

pressures may affect operation

PLEASE REVIEW THIS ENTIRE

INSTALLATION AND OPERA-

TION MANUAL FOR ADDITIONAL

INSTRUCTIONS.

BETTER INSTALLATION:

Vertical & Horizontal Installation

(Up and Out)

Some natural draft aids venting. Wind

pressures may still affect operation

BEST INSTALLATION:

Vertical Installation

(Straight Up)

Natural draft improves operation and

negative effects from wind

VENTING TYPE

a: PL-Vent Pipe / Pellet Vent (w/stainless interliner)

b: Stainless Steel flex liner may be used inside existing flue

or chimney (woodstove replacement applications)

CAUTION: Do not use Type B-Vent Pipe

REQUIRES 3”

DIAMETER STANDARD

PL-VENT / PELLET PIPE

With listed termination kit. If

installation requires in excess of

11’ of pipe, it is recommended a

4” diameter pipe be used.

MANUFACTURED

HOME

Requires outside air for com-

bustion. Use a galvanized or

stainless steel pipe for duct.

Minimum duct size 1-5/8” dia.

CLEARANCES TO

COMBUSTIBLES

Ensure all clearances are main-

tained in accordance to instruc-

tions contained on product

safety label and in compliance

with pipe/venting requirements.

POWER SUPPLY

Must have proper polarity and

be grounded.

Note: Use of an extension

cord may adversely effect the

performance of your unit.

Seal all

Venting Joints:

Use RTV

(high temp silicone)

INSTALLATION TIPS

Select Your Installation Type

Advertising