Troubleshooting & repair, Output rectifier bridge test (continued) – Lincoln Electric VANTAGE 400 User Manual

Page 106

Advertising
background image

FIGURE F.14

OUTPUT RECTIFIER BRIDGE TEST (CONTINUED)

TEST PROCEDURE

1. Turn the engine off.

2. Perform the Case Cover Removal procedure.

3. Perform the Chopper Module Capacitor

Discharge procedure.

Electrically isolate the three-phase input
terminals of the output bridge rectifier as
follows:

4. Mark leads W1, W2, and W3 so they can be

properly reconnected after the test is complete.
Remove these leads and position them so they
do not come in contact with any part of the rec-
tifier. See Figure F.15. See wiring diagram.

Electrically isolate the DC output terminals
of the rectifier:

5. Mark the leads connected to the positive and

negative terminals of the output bridge rectifier
to assure that they can be reconnected prop-
erly. See Figure F.15.

6. Remove leads W4, W5, and W10 from the

positive terminal of the Rectifier, and remove
leads W6 and W11 from the negative terminal.
Position these leads so they do not come to
contact with any part of the rectifier. See
Figure F.15.
See the wiring diagram..

TROUBLESHOOTING & REPAIR

F-58

F-58

VANTAGE® 400

X1

DC+

DC-

D5

D6

D3

D4

D1

D2

AC3

AC2

AC1

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

Advertising