Troubleshooting & repair, Chopper module function test (continued) – Lincoln Electric VANTAGE 400 User Manual

Page 110

Advertising
background image

B1

B2

B3

B6

B5

B4

23

25

SL302

SL301

HL W9

HL W4

HL W6

SL14

SL13

B8

HL W8

HL W5

HL W11

LED1

LED1

LED4

LED4

LED2

LED2

LED3

LED3

L12683-1

LED1 (B1,B2,B3)
Chopper Working

LED3 (B4,B5,B6)
Chopper Working

LED4
PWM Signal

LED2
Voltage from
Rectifier

FIGURE F.16 - CHOPPER MODULE CONNECTIONS

CHOPPER MODULE FUNCTION TEST (CONTINUED)

TEST PROCEDURE

1. Perform

the

Case

Cover

Removal

Procedure.

2. Make sure that there is nothing plugged into

either of the Amphenol receptacles.

3. Place idle switch in the “HIGH” position.

4. Place the mode switch in the “CC-STICK” posi-

tion.

5. Place the Welding Terminal switch in the

“REMOTELY CONTROLLED” position.

6. Start the engine and allow it to stabilize at high

idle RPM.

7. Check for 80 to 100 VDC at terminals B1- to

B2+ and B4- to B5+ of the chopper module.
See wiring diagram and figure #1.

8. If the correct DC voltage is not present at ter-

minals B1- to B2+ and B4- to B5+, check for
damaged conductors or faulty connections
between the chopper module, the output recti-
fier, and the stator weld winding. See Figure
F.17. See the wiring diagram. Perform the
Stator Voltage Tests, and the Output
Rectifier Test
.

9. If the correct voltage is present at terminals

B1- to B2+ and B4- to B5+ of the chopper mod-
ule, check for DC voltage at the chopper mod-
ule terminals B2+ to B3-, and B5+ to B6-, If sig-
nificant voltage is present, disconnect leads
#23 and #25 from the chopper module PC
board. If voltage is still present, the copper
module is shorted and should be replaced.

10. If the voltage drops to 0 VDC after the #23 and

#25 leads have been disconnected, the control
PC board is driving the chopper module when
it should not be doing so. Reconnect the #23
and #25 leads and perform the Weld Control
Board Gate Drive Test
.

11. Reconnect leads #23 and #25, and place the

Welding Terminal switch in the “WELD TERMI-
NALS ON” position.

12. Check for about 58 VDC between Chopper

Module Terminals B2+ to B3-, and B5+ to B6
and between the welder output terminals. See
Figure F.16. See the wiring diagram.

TROUBLESHOOTING & REPAIR

F-62

F-62

VANTAGE® 400

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

Advertising