FIGURE F.2 - DIODE TEST TABLE

CHOPPER MODULE RESISTANCE TEST (CONTINUED)

TROUBLESHOOTING & REPAIR

F-67

F-67

VANTAGE® 400

(+) Lead

(-) Lead

Diode Bias

and Expected

Test Result

B5

B6

6K to 9K

B6

B5

6K to 9K

B4

B5

200k or higher

B5

B4

400k or higher

B4

B6

200k or higher

B6

B4

400k or higher

B2

B3

6K to 9K

B3

B2

6K to 9K

B4

B2

200k or higher

B2

B4

400k or higher

B4

B3

200k or higher

B3

B4

400k or higher

OHMMETER

OHMMETER

READING

Chopper

T

erminal

Connections

5. Reconnect all leads.

6. The chopper module screw connection should be lightened to 50-60 inch-pounds.

7. Perform the Case Cover Replacement procedure.