The table f.1, Rectifier t erminal connections, Troubleshooting & repair – Lincoln Electric VANTAGE 400 User Manual
Page 108
Advertising
TROUBLESHOOTING & REPAIR
F-60
F-60
VANTAGE® 400
(+) Lead
(-) Lead
Diode Bias
and Expected
Test Result
AC1
DC(+)
FORWARD BIAS
(Low Resistance)
AC2
DC(+)
FORWARD BIAS
(Low Resistance)
AC3
DC(+)
FORWARD BIAS
(Low Resistance)
DC(-)
AC1
FORWARD BIAS
(Low Resistance)
DC(-)
AC2
FORWARD BIAS
(Low Resistance)
DC(-)
AC3
FORWARD BIAS
(Low Resistance)
AC1
DC(-)
REVERSE BIAS
(High Resistance)
AC2
DC(-)
REVERSE BIAS
(High Resistance)
AC3
DC(-)
REVERSE BIAS
(High Resistance)
DC(+)
AC1
REVERSE BIAS
(High Resistance)
DC(+)
AC2
REVERSE BIAS
(High Resistance)
DC(+)
AC3
REVERSE BIAS
(High Resistance)
11. Reconnect all leads.
12. Perform the Case Cover replacement Procedure.
TABLE F.1 – DIODE TEST TABLE
Test Instrument
Rectifier
T
erminal
Connections
Advertising