FILTER
CAPACITOR
FIELD DIODE
RECTIFIER BRIDGE
FIGURE F.20 – DOOR REMOVAL
STATOR/ROTOR REMOVAL AND REPLACEMENT PROCEDURE
(CONTINUED)
PROCEDURE
9. Disconnect plug J30 at the right front side. See
Figure F.20.
10. Using the slot head screw driver, disconnect
leads #200B, #200A(+) and #201A(-) from the
filter capacitor. Label the leads.
11. Label and remove leads 5H, 200, 200A, 6A,
201A, 5H from the field bridge rectifier. See
Figure F.20.