Troubleshooting & repair, Retest after repair – Lincoln Electric VANTAGE 400 User Manual

Page 152

Advertising
background image

TROUBLESHOOTING & REPAIR

F-104

F-104

VANTAGE® 400

RETEST AFTER REPAIR

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics. OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

1300 - 1400

N/A

High Idle

1860 - 1890

1800

WELDER DC (STICK) OUTPUT (ARC control @ -10)

Mode Selector

Output Control

Open Circuit

Load Volts

Load Amps

Switch

Volts

Stick (CC)

Maximum

55-60

36-38

400

WELDER CV (WIRE) OUTPUT (ARC Control @ +10)

Mode Selector

Output Control

Open Circuit

Load Volts

Load Amps

Switch

Voltage

CV

Maximum

55-60

36-38

290-310

CV

Minimum

55-60

17-19

220

TOUCH START TIG (ARC Control @ +10)

Mode Selector

Output Control

Open Circuit

Load Volts

Load Amps

Switch

Voltage

TIG

Maximum

10-15

18-22

240-260

TIG

Minimum

10-15

Short Circuit

18-28

AUXILIARY POWER OUTPUT

240 Volt Receptacle

120 Volt Receptacles

Open Circuit

Load Volts

Load Amps

Open Circuit

Load Volts

Load Amps

Voltage

Voltage

230-264*

216-252

50

115-132

108-126

20

* Upper limit reflects cold machine, voltage will be below 132/264 for machine at normal operating temperature.

42 VOLT WIRE FEEDER POWER

Open Circuit Voltage

Load Volts

Load Amps

40-50

38-48

8=.5

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

Advertising