OUTPUT RECTIFIER BRIDGE TEST (CONTINUED)

7. Check for grounds by placing one of the ohm

meter probes on a clean, unpainted metal sur-
face of the machine. Touch the other probe to
each of the five rectifier terminals. The resis-
tance to chassis ground from each terminal
should be very high, 500,000 (500K) ohms
minimum. If the resistance reading is less than
specified, the rectifier is grounded and should
be replaced.

8. If using diode checker or a multimeter with

diode check functionality, read and understand
the instructions that accompany your test
equipment.

9. If using an analog ohmmeter, the forward bias

test will indicate low resistance and the reverse
bias test will indicate high resistance. Precise
ohm values for this test will vary depending on
the test equipment used.

NOTE: A digital Ohmmeter is not recommended for

this test. A typical digital Ohmmeter does
not provide enough voltage or current flow
to reliably test the diodes used in this recti-
fier.

10. Test all of the diode groups per the Table F.1.

TROUBLESHOOTING & REPAIR

F-59

F-59

VANTAGE® 400

OR

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Section

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

R

etur

n

to

Mast

er

T

OC

Advertising