TROUBLESHOOTING & REPAIR

F-37

F-37

IDEALARC CV-400

SCR/DIODE RECTIFIER ASSEMBLY

REMOVAL AND REPLACEMENT (continued)

FIGURE F.19 – SCR/DIODE ASSEMBLY DETAILS

PROCEDURE

1. Remove the main input supply power to the

machine.

2. With the 5/16” nut driver, remove the case

top and sides.

3. Remove the glastic stiffeners (one on right

side-two on left side). See Figure F.19.

4. Remove lead #220 from the right side of the

negative heat sink plate.

5. Remove the positive capacitor lead and

shunt from the positive heat sink plate. See
Figure F.19.

6. Remove the choke and negative capacitor

leads from the left side of the negative heat
sink plate. See Figure F.19.

7. Remove the gate leads from the control

board (plug P3).

8. Remove plug P5 from the snubber board.

Also remove lead #224 from the positive
output lead. Remove lead #225 from the
negative output lead. Remove the green
ground lead from the front panel.

9. Remove the three heavy aluminum sec-

ondary leads from the SCR finned heat sinks.

10. Remove the four nuts and associated wash-

ers that hold the SCR/diode assembly to the
mounting brackets.

11. Carefully lift and remove the SCR/diode heat

sink assembly from the machine. Note: It
may be necessary to loosen the four sheet
metal screws that hold the front panel to the
base. Carefully lift and pull out the front
panel to allow clearance for SCR/diode

assembly removal. Clear any necessary
leads that might hinder removal.

12. For reassembly, carefully place the SCR/

diode assembly into position on the mount-
ing bracket and reinstall the washers and
nuts. Tighten the front panel to base if it was
loosened earlier.

13. Replace and tighten the four nuts and lock-

washers that hold the SCR/diode assembly
to the mounting brackets.

14. Reattach the three heavy aluminum sec-

ondary leads to the SCR finned heat sinks.
Apply a thin coating of Dow Corning 340
heat sink compound (Lincoln E1868) to con-
nection points.

15. Connect the green ground lead to the front

panel, lead #225 to the negative output lead,
and lead #224 to the positive output lead.

16. Connect plug P5 to the snubber board and

plug P3 to the control board.

17. Connect the choke and negative capacitor

lead to the left side of the negative heat sink
plate. See Figure F.19. Apply a thin coating
of Dow Corning 340 heat sink compound
(Lincoln E1868) to connection points.

18. Connect the positive capacitor lead and

shunt to the positive heat sink plate. See
Figure F.19.

19. Install the glastic stiffeners to the left and

right sides. See Figure F.19. Apply a thin
coating of Dow Corning 340 heat sink com-
pound (Lincoln E1868) to connection points.

20. Install the case top and sides.