INSTALLATION

A-2

A-2

IDEALARC CV-400

TECHNICAL SPECIFICATIONS - IDEALARC CV-400

INPUT - THREE PHASE ONLY

Standard Voltage

Input Current at Rated Output

230/460

77A/39A @ 400A 36V

RATED OUTPUT

Duty Cycle

Welding Output

Volts at Rated Amps

100%

400

36*

60%

450

38

50%

500

40

OUTPUT

Current

Voltage

Maximum Open

Auxiliary

Range

Range

Circuit Voltage

Power

60 - 500 Amps

12 - 42 Volts

46 VDC

115 VAC, 10 Amps

42 VAC, 10 Amps

RECOMMENDED INPUT WIRE AND FUSE SIZES

Fuse

Type 75° C

Type 75° C

Input Voltage/

Input Amps

(Super Lag)

Copper Wire in

Copper Ground

Frequency

Rating on

or Breaker

Conduit AWG

Wire in Conduit

Volts/Hz

Nameplate

Size

(IEC) Sizes

AWG (IEC) Sizes

230

77

125

3 (27 mm

2

)

6 (13 mm

2

)

460

39

60

8 (8.4 mm

2

)

10 (5.3 mm

2

)

PHYSICAL DIMENSIONS

Height

2

Width

Depth

Weight

27.5 in. (699 mm)

22.2 in. (565 mm)

32.0 in. (813 mm)

357 lbs. (162 kg)

* No added capacity over NEMA rated 36V at 400 amps.