D as shown in figure f.8, Troubleshooting & repair, Main transformer (t1) voltage test (continued) – Lincoln Electric IDEALARC SVM136-A User Manual
Page 60
Advertising
TROUBLESHOOTING & REPAIR
F-20
F-20
IDEALARC CV-400
Plug P1 PHASE ANGLE WINDING VOLTAGES
From Lead #
To Lead #
Expected VAC
201
204
21 VAC
202
204
21 VAC
203
204
21 VAC
MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)
FIGURE F.8 – CONTROL BOARD PLUG P1 LOCATION
G2629-[
]
CV-400/CV-500-I CONTROL
Plug P1
#201
#202
#203
#204
Plug P3