CONNECTING THE LN-8 OR LN-9 TO THE
IDEALARC CV-400

1. Set the CV-400 POWER toggle switch to the OFF (0)

position.

2. Disconnect main AC input power to the CV-400.

3. Connect the wire feeder control cable leads to the

CV-400 terminal strip as shown in Figure C.5.

4. Connect the wire feeder control cable ground lead

to the frame terminal marked .

5. Extend wire feeder control cable lead #21 so it can

be connected directly to the work piece.

a. Make a bolted connection using AWG #14 or

larger insulated wire. Tape the bolted connection
with insulating tape.

b. An S-16586- X remote voltage sensing work lead

is available for this purpose.

c. Keep the #21 lead electrically separate from the

work cable circuit and connection.

d. Tape the #21 lead to the work cable for ease of

use.

NOTE: Using the extended #21 lead eliminates the
need to use the LN-9's remote work lead accesso-
ry, which has a direct work lead jack.

6. Connect the LN-9 wire feeder control jumpers on

the Voltage Control board. See LN-9 operator's
manual.

NOTE: The connection diagram shown in Figure C.5
shows the electrode connected for positive polarity.
To change polarity:

a. Set the CV-400 POWER toggle switch to the OFF

(0) position.

b. Move the electrode cable to the negative (-) out-

put terminal.

c. Move the work cable to the positive (+) output

terminal.

d. Set the VOLTMETER toggle switch on power

source to negative (-).

e. Set the voltmeter toggle switch on feeder (if

equipped) to match electrode polarity.

ACCESSORIES

C-7

C-7

IDEALARC CV-400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FIGURE C.5

LN-8 OR LN-9 WIRE FEEDER CONNECTION TO THE IDEALARC CV-400

+

-

ELECTRODE
CABLE TO
AUTOMATIC
EQUIPMENT

TO
WORK

NEGATIVE

POSITIVE

TO

INPUT

CABLE

LN-8 ORLN-9
WIRE FEEDER
CONTROL CABLE

21

4

2

BLANK

31

32

75

76

77

GND

77

76

75

32

31

2

4

21

TERMINAL

STRIPS

Advertising