INPUT LINE VOLTAGE, CONTACTOR
AND MAIN TRANSFORMER

The desired three-phase input power is connected to
the CV-400 through an input contactor, located in the
input box at the rear of the machine. Two phases of the
input line are also connected to the control transformer,
which, through the power switch, supplies power to
activate the input contactor.

A reconnect panel allows the user to configure the
machine for the desired input voltage. This AC voltage
is applied to the primary of the main transformer.

The transformer changes the high voltage, low current
input power to a lower voltage, higher current output.

The finishes or "neutrals" of the main secondary coils
are connected together, and the three starts of the sec-
ondary windings are connected to the rectifier bridge
assembly. In addition, the main transformer has sepa-
rate and isolated 115VAC and 42VAC auxiliary wind-
ings. The 115VAC is available at the terminal strip and
the 14 pin amphenol and is protected by a 10 amp cir-
cuit breaker. The 42VAC is available at the 14 pin
amphenol only and is also protected by a 10 amp cir-
cuit breaker. The three 21VAC phase angle windings
are also housed in the main transformer assembly.
These windings provide power and "timing" for the con-
trol board.

THEORY OF OPERATION

E-2

E-2

IDEALARC CV-400

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.

FIGURE E.2 – INPUT LINE VOLTAGE, CONTACTOR AND MAIN TRANSFORMER

FAN

115VAC

42VAC

REMOTE

CONTROL

TO

CONTROL

BOARD

CONTROL BOARD

OUTPUT

CONTROL

CONTROL

TRANSFORMER

POWER

SWITCH

R
E
C
O
N
N
E
C
T

INPUT

CONTACTOR

T
E
R
M

I

N

A

L

S
T
R

I

P

TRANSFORMER

MAIN

SCR

DIODE

HYBRID BRIDGE

/

CAPACITORS

SHUNT

NEGATIVE

OUTPUT

TERMINAL

POSITIVE

OUTPUT

TERMINAL

OUTPUT

G

A
T
E

S

I

G

N

A
L

S

F
E
E
D
B
A
C
K

s

F
E
E
D
B
A
C
K

14 PIN AMPHENOL